Commercial Ventilation Location: Greenwich, CT • Completed: 2025-06-18

Greenwich Woods Facility - Commercial Attic Ventilation & Cooling

Dual commercial-grade high-CFM attic ventilation fans installed to regulate roof-space heat buildup, dramatically lowering summer air conditioning cooling loads.

Service Capacity 40 Amps
Voltage & Phase 120V 1-Phase Commercial Branch
Switchgear / Panel Eaton Pow-R-Line Panelboard
Feeder Conductors 12/2 MC Cable Armor Clad
Permit & Code Status CT-GRNW-2025-1109 (Passed)

Engineering Scope & Project Overview

Engineered an energy-saving attic airflow evacuation solution for the multi-story Greenwich Woods commercial facility in Fairfield County. Installed dual high-velocity louvered fans driven by digital dual-temperature and relative humidity sensors.

Greenwich Woods Facility - Commercial Attic Ventilation & Cooling

The Field Challenge

Severe attic heat build-up exceeding 140°F was overloading rooftop air handlers, causing frequent HVAC breaker trips and excessive utility bills.

The Master Electrician Solution

Ran dedicated 20A branch circuits from the third-floor commercial panel to automated dual-speed exhaust fans with emergency fire-rated fusible thermal link disconnect switches.

Bill of Materials & Component Specifications

Commercial and residential installations utilize commercial-grade, UL-listed hardware meeting NEC 2023 specifications:

Component Description Quantity Manufacturer
Commercial High-Velocity Gable Exhaust Fan (3,500 CFM) 2 Air King
Digital Line-Voltage Thermostat & Dehumidistat Controller 2 Honeywell
12/2 Solid Metal Clad (MC) Armor Cable 120 ft Southwire
Fire-Safety Thermal Cutoff Disconnect Switch 2 Square D
"CF Electrical diagnosed our ventilation issue immediately. The fans lowered ambient attic temperatures by 32 degrees and our AC units run smoothly now."
— David Wilson, Commercial Facility Director

National Electrical Code (NEC 2023) Compliance & Safety Standards

This project was installed by a Connecticut Licensed Master Electrician (License #191788-E1) following Article 215 (Feeders), Article 240 (Overcurrent Protection), Article 250 (Grounding and Bonding), and Article 408 (Switchboards and Panelboards).

Grounding verified: Continuous equipment grounding conductor bonded to branch panel. Surge Protective Device (SPD) integrated: Yes, Type 1/2 Whole-System.