CT DCP LIC #191788-E1 | CT DOT CERTIFIED DBE | CT DOL APPRENTICESHIP SPONSOR
DISPATCH: (203) 565-4506
CF Electrical Service
CF ELECTRICAL SERVICE
Master Electrician Lic #191788-E1
Bucket Truck Lighting Location: Torrington, CT • Completed: 2025-11-12

Commercial Plaza Parking Lot Lighting & LED Pole Head Retrofit

Commercial parking lot lighting modernization replacing inefficient 400W metal halide fixtures with precision Type III optical LED shoebox luminaires using bucket truck service.

Service Capacity 60 Amps
Voltage & Phase 277V Lighting Circuit
Switchgear / Panel GE Spectra Commercial Panel
Feeder Conductors #8 AWG THHN in Underground RMC
Permit & Code Status CT-TORR-2025-0631 (Passed)

Engineering Scope & Project Overview

Upgraded exterior lighting across a 3-acre commercial shopping center parking lot in Torrington, CT. The project eliminated dark safety zones, satisfied municipal commercial lighting code compliance, and integrated automated astronomical dusk-to-dawn time controls.

Commercial Plaza Parking Lot Lighting & LED Pole Head Retrofit

The Field Challenge

Working on 25-foot steel poles in high-traffic retail parking areas without interfering with ongoing customer vehicle flow.

The Master Electrician Solution

Utilized CF Electrical's aerial bucket truck during early morning windows to remove ballasts, inspect internal pole wiring, and mount 150W LED area fixtures with 10kV surge suppressors.

Bill of Materials & Component Specifications

Commercial and residential installations utilize commercial-grade, UL-listed hardware meeting NEC 2023 specifications:

Component Description Quantity Manufacturer
150W Type III Optical LED Commercial Area Fixtures (5000K) 14 RAB Lighting
Rotatable 7-Pin Locking Photocell Sensors 14 Intermatic
10kV In-Pole Surge Suppression Modules 14 Littlefuse
Astronomical 365-Day Electronic 2-Channel Time Switch 1 Intermatic
"CF Electrical keeps our retail properties safe, bright, and code compliant. Their bucket truck equipment lets them handle pole lights fast and professionally."
— Marcus Vance, PE, Property Asset Manager

National Electrical Code (NEC 2023) Compliance & Safety Standards

This project was installed by a Connecticut Licensed Master Electrician (License #191788-E1) following Article 215 (Feeders), Article 240 (Overcurrent Protection), Article 250 (Grounding and Bonding), and Article 408 (Switchboards and Panelboards).

Grounding verified: Individual pole grounding electrode rods tested <15 ohms. Surge Protective Device (SPD) integrated: Yes, Type 1/2 Whole-System.